A SiNP–Chitosan Nanocomposite Converts Hydrophobic 3D-Printed Microchannels into Whole-Blood-Operable Nanoplasmonic Biosensors

Theodor Bilharz Research Institute

Bibliographic Information

Authors: Hassan Y.M.; Attia M.S.; El-Tantawi H.; Rabie Ali I.; M. El-Husseini D.; Abou-Omar M.N.

Journal: ACS Biomaterials Science and Engineering

Publisher: American Chemical Society

Publication Date: 3 June 2026

Volume / Issue: Volume 12 / Issue 7

Pages: 3738–3757

ISSN: 23739878

DOI: 10.1021/acsbiomaterials.6c00531

Scopus: View on Scopus

PubMed: 42233753

Document Type: Article


Authors and Affiliations

Hassan Y.M., Department of Zoology, Faculty of Science, Ain Shams University, Abbassia, Cairo, 11566, Egypt; Attia M.S., Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, 11623, Saudi Arabia; El-Tantawi H., Department of Zoology, Faculty of Science, Ain Shams University, Abbassia, Cairo, 11566, Egypt; Rabie Ali I., Department of Immunology and Treatment Evaluation, Theodore Bilharz Research Institute, Giza, 12411, Egypt; M. El-Husseini D., Nanomaterial Research and Synthesis unit, Animal Health Research Institute, Agriculture Research center, Giza, 12618, Egypt; Abou-Omar M.N., Department of Chemistry, Faculty of Science, Sadat University, Sadat City, 32897, Egypt


Abstract

A single drop of unprocessed whole blood, placed at the inlet of a 3D-printed cartridge, yields a quantitative cancer biomarker result in under 15 min—without centrifugation, pipettes, cold-chain reagents, or any laboratory instrument. This is made possible by a silica nanoparticle–chitosan (SiNP–chitosan) nanocomposite that transforms a hydrophobic stereolithography-printed substrate into a near-superhydrophilic, antifouling interface (contact angle 74.3° → 25.3°; Laplace pressure amplified 5.2-fold; fibrinogen adsorption reduced 12-fold), driving autonomous capillary plasma separation directly from finger-prick blood without any external actuation. Anti-GPC3-functionalized gold nanoparticles (AuNPs, ∼30 nm) embedded in chitosan hydrogel beads within the same cartridge transduce antigen binding via localized surface plasmon resonance (LSPR) into two simultaneous, independent optical signals, namely, instrument-free RGB colorimetry (TCS3200/Arduino) for point-of-care use and laboratory-grade LSPR ratiometry for cross-validation—providing intrinsic dual-channel confirmation that no single-transducer platform can match. Glypican-3 (GPC3), an HCC-specific biomarker superior to α-fetoprotein, is detected at LOD = 0.24 ng mL−1 directly from unprocessed whole blood in the same step that separates the plasma. A stereolithography-fabricated device (45 × 18 × 6 mm) incorporates a geometry-programmed micropillar array coated with a silica nanoparticle–chitosan (SiNP–chitosan) nanocomposite. Anti-GPC3-functionalized AuNPs (∼30 nm; TEM core 30.2 ± 2.8 nm) transduce antigen binding into LSPR ratiometric shifts (A₅₈₀/A₅₂₀) and a correlated RGB colorimetric signal, validated in a DEN-induced murine HCC model. The results are as follows: contact angle reduced from 74.3° to 25.3°; Laplace pressure amplified 5.2-fold (86 to 451 Pa); plasma recovery 35–42% of total blood input volume within 30 s; LOD = 0.24 ng mL−1 (LSPR channel)/0.31 ng mL−1 (RGB channel); CV < 10% (both channels); spike recovery 97.3%; ELISA agreement R2 ≈ 0.99; tumor burden correlation R2 ≈ 0.98; diagnostic AUC = 1.00 (95% CI: 0.993–1.000; per timepoint: week 9, AUC = 0.98; week 11, 0.99; weeks 13–16, 1.00) in a controlled inbred murine DEN-HCC model (n = 10 per group). This AUC = 1.00 result must be interpreted in context: it was obtained in a tightly controlled, single-strain, single-sex, small-sample (n = 10 per group) murine cohort and reflects ceiling-level discrimination in a maximally homogeneous preclinical setting. It is not a projection of human diagnostic performance. Such ceiling-level AUC values in small homogeneous animal cohorts are well-documented in biosensor proof-of-concept literature Hanley and McNeal. Radiology 1982, 143, 29–36 and carry a recognized risk of optimistic bias: the controlled model eliminates the inter-individual biological heterogeneity, comorbidity, and preanalytical variability that will reduce AUC substantially in human populations. The AUC is reported to characterize analytical discrimination power of the platform under maximally favorable conditions, not to claim clinical diagnostic performance. This preclinical proof-of-concept platform demonstrates, in a murine DEN-HCC model, a broadly applicable framework for decentralized nanoscale cancer biomarker diagnostics. The RGB channel enables fully instrument-free point-of-care operation; the LSPR channel provides laboratory-grade cross-validation. Prospective human clinical validation is planned before clinical deployment. © 2026 American Chemical Society


Keywords

3D-printed microfluidics; glypican-3; gold nanoparticles; hepatocellular carcinoma; localized surface plasmon resonance; nanocomposite surface engineering; point-of-care diagnostics; Animals; Biomarkers, Tumor; Biosensing Techniques; Chitosan; Glypicans; Gold; Humans; Hydrophobic and Hydrophilic Interactions; Liver Neoplasms; Metal Nanoparticles; Nanocomposites; Printing, Three-Dimensional; Silicon Dioxide; Surface Plasmon Resonance; Biomarkers; Biosensors; Blood; Contact angle; Diagnosis; Fiber optic sensors; Gold compounds; Laplace transforms; Microchannels; Microfluidics; Plasmonic nanoparticles; Projectiles; Silica nanoparticles; Stereolithography; Substrates; Transducers; alpha fetoprotein; chitosan nanocomposite; fibrinogen; glypican 3; gold nanoparticle; hydrogel; nanocomposite; silica nanoparticle; tumor marker; unclassified drug; glypican; GPC3 protein, human; metal nanoparticle; 3d-printed microfluidic; Point of care diagnostic; Surface engineering; Whole blood; adsorption; adult; animal experiment; animal model; antifouling coating; antigen binding; Article; benchmarking; biological variation; blood sampling; body composition; calibration; cancer diagnosis; cancer staging; capillary; capillary blood; centrifugation; cohort analysis; colorimetry; comorbidity; contact angle goniometry; controlled study; cross validation; diagnostic accuracy; diagnostic test accuracy study; ellipsometry; enzyme linked immunosorbent assay; hemostasis; hydrophobicity; intermethod comparison; limit of detection; liver cell carcinoma; male; mouse; nonhuman; optimism bias; photon correlation spectroscopy; point of care testing; pressure; profilometry; proof of concept; quantitative analysis; receiver operating characteristic; sensitivity and specificity; surface area; surface property; synthesis; three dimensional printing; tumor burden; tumor volume; wettability; animal; chemical phenomena; chemistry; devices; genetic procedures; human; immunology; liver tumor; procedures


Citation Information

Scopus Citations: 0


For comprehensive information about the Theodor Bilharz Research Institute (TBRI), its institutional activities, scientific and research achievements, clinical and hospital services, and the diverse expertise offered through its 22 specialized research and clinical departments, as well as opportunities for professional training, specialized workshops, and scientific conferences, readers are invited to visit the Institute’s official website.

The website provides regularly updated information on the Institute’s latest news, research activities, scientific initiatives, clinical services, institutional programs, and academic and professional opportunities.

English Website: https://www.tbri.sci.eg/en/

Arabic Website: https://www.tbri.sci.eg/ar/

Prepared and Uploaded by:

Abdalla F. Abdalla

Electronic Portal Unit

Electronic Portal Unit

Popular Posts

A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium–salicylate luminescent platforms for GPC3-targeted early HCC diagnosis

Mytilus edulis-mediated green synthesis of selenium nanoparticles with antimicrobial and molluscicidal applications

Holothuria arenicola Extract-Loaded Polycaprolactone Nanocapsules Attenuate Bile Duct Ligation-Induced Acute Liver Injury

Corrigendum to ‘Eco-friendly approach for the removal and simultaneous detection of cyanide toxins from drinking and wastewater sources’ [Environ. Pollut. 385 (2025) 127094]

Microbial levan potentiates hepatic retention and antitumor activity of a PEGylated benzimidazole–curcumin nanocomplex through TLR2–FXR/FGF15-associated immunometabolic remodeling in experimental liver cancer

Climate change and schistosomiasis: the impact of rising temperatures on snails transmitting schistosoma species

Upcycling low-density polyethylene waste into 1D fishbone nanofibers and 2D graphene nanoribbons for enhanced antibacterial applications