Spinal cord injury after thoracic endovascular aortic aneurysm repair; [Lésion de la moelle épinière après réparation endovasculaire d’un anévrisme de l’aorte thoracique]

Theodor Bilharz Research Institute

Bibliographic Information

Authors: Awad H.; Ramadan M.E.; El Sayed H.F.; Tolpin D.A.; Tili E.; Collard C.D.

Journal: Canadian Journal of Anesthesia

Publisher: Springer New York LLC

Publication Date: 10 October 2017

Volume / Issue: Volume 64 / Issue 12

Pages: 1218–1235

ISSN: 0832610X

DOI: 10.1007/s12630-017-0974-1

Scopus: View on Scopus

PubMed: 29019146

Document Type: Review

Access: All Open Access; Bronze Open Access; Green Open Access


Authors and Affiliations

Awad H., Department of Anesthesiology, Wexner Medical Center, The Ohio State University, Doan Hall 534, 410 West 10th Avenue, Columbus, 43210, OH, United States; Ramadan M.E., Department of Anesthesiology, Wexner Medical Center, The Ohio State University, Doan Hall 534, 410 West 10th Avenue, Columbus, 43210, OH, United States, Department of Anesthesiology, Theodor Bilharz Research Institute, Giza, Egypt; El Sayed H.F., Division of Vascular Diseases & Surgery, Wexner Medical Center, The Ohio State University, Columbus, OH, United States; Tolpin D.A., Division of Cardiovascular Anesthesiology, The Texas Heart Institute, Baylor St. Luke’s Medical Center, Houston, TX, United States; Tili E., Department of Anesthesiology, Wexner Medical Center, The Ohio State University, Doan Hall 534, 410 West 10th Avenue, Columbus, 43210, OH, United States; Collard C.D., Division of Cardiovascular Anesthesiology, The Texas Heart Institute, Baylor St. Luke’s Medical Center, Houston, TX, United States


Abstract

Purpose: Thoracic endovascular aortic aneurysm repair (TEVAR) has become a mainstay of therapy for aneurysms and other disorders of the thoracic aorta. The purpose of this narrative review article is to summarize the current literature on the risk factors for and pathophysiology of spinal cord injury (SCI) following TEVAR, and to discuss various intraoperative monitoring and treatment strategies. Source: The articles considered in this review were identified through PubMed using the following search terms: thoracic aortic aneurysm, TEVAR, paralysis+TEVAR, risk factors+TEVAR, spinal cord ischemia+TEVAR, neuromonitoring+thoracic aortic aneurysm, spinal drain, cerebrospinal fluid drainage, treatment of spinal cord ischemia. Principal findings: Spinal cord injury continues to be a challenging complication after TEVAR. Its incidence after TEVAR is not significantly reduced when compared with open thoracoabdominal aortic aneurysm repair. Nevertheless, compared with open procedures, delayed paralysis/paresis is the predominant presentation of SCI after TEVAR. The pathophysiology of SCI is complex and not fully understood, though the evolving concept of the importance of the spinal cord’s collateral blood supply network and its imbalance after TEVAR is emerging as a leading factor in the development of SCI. Cerebrospinal fluid drainage, optimal blood pressure management, and newer surgical techniques are important components of the most up-to-date strategies for spinal cord protection. Conclusion: Further experimental and clinical research is needed to aid in the discovery of novel neuroprotective strategies for the protection and treatment of SCI following TEVAR. © 2017, Canadian Anesthesiologists' Society.


Keywords

Aortic Aneurysm, Thoracic; Endovascular Procedures; Humans; Monitoring, Intraoperative; Risk Factors; Spinal Cord Injuries; Spinal Cord Ischemia; anesthesia; arterial embolization; autonomic dysfunction; blood pressure regulation; cerebrospinal fluid drainage; clinical feature; collateral circulation; endovascular aneurysm repair; human; hypothermia; internal iliac artery; intraoperative monitoring; left subclavian artery; minimally invasive segmental artery coil embolization; motor evoked potential; near infrared spectroscopy; neuroprotection; nonhuman; open surgery; paralysis; paresis; perioperative period; priority journal; Review; risk factor; risk reduction; sensory evoked potential; spinal cord injury; surgical risk; surgical technique; temporary aneurysm sac perfusion; thoracic aortic surgery; thoracoabdominal aorta aneurysm; endovascular surgery; pathophysiology; procedures; thoracic aorta aneurysm


Citation Information

Scopus Citations: 106


For comprehensive information about the Theodor Bilharz Research Institute (TBRI), its institutional activities, scientific and research achievements, clinical and hospital services, and the diverse expertise offered through its 22 specialized research and clinical departments, as well as opportunities for professional training, specialized workshops, and scientific conferences, readers are invited to visit the Institute’s official website.

The website provides regularly updated information on the Institute’s latest news, research activities, scientific initiatives, clinical services, institutional programs, and academic and professional opportunities.

English Website: https://www.tbri.sci.eg/en/

Arabic Website: https://www.tbri.sci.eg/ar/

Prepared and Uploaded by:

Abdalla F. Abdalla

Electronic Portal Unit

Electronic Portal Unit

Popular Posts

A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium–salicylate luminescent platforms for GPC3-targeted early HCC diagnosis

Mytilus edulis-mediated green synthesis of selenium nanoparticles with antimicrobial and molluscicidal applications

Holothuria arenicola Extract-Loaded Polycaprolactone Nanocapsules Attenuate Bile Duct Ligation-Induced Acute Liver Injury

Corrigendum to ‘Eco-friendly approach for the removal and simultaneous detection of cyanide toxins from drinking and wastewater sources’ [Environ. Pollut. 385 (2025) 127094]

Microbial levan potentiates hepatic retention and antitumor activity of a PEGylated benzimidazole–curcumin nanocomplex through TLR2–FXR/FGF15-associated immunometabolic remodeling in experimental liver cancer

Climate change and schistosomiasis: the impact of rising temperatures on snails transmitting schistosoma species

Upcycling low-density polyethylene waste into 1D fishbone nanofibers and 2D graphene nanoribbons for enhanced antibacterial applications