Detour technique, Dipping technique, or IIeal bladder flap technique for surgical correction of uretero-ileal anastomotic stricture in orthotopic ileal neobladder

Theodor Bilharz Research Institute

Bibliographic Information

Authors: Wishahi M.; Elganzoury H.; Elkhouly A.

Journal: International Braz J Urol

Publisher: Brazilian Society of Urology

Publication Date: August 2015

Volume / Issue: Volume 41 / Issue 4

Pages: 796–803

ISSN: 16775538

DOI: 10.1590/S1677-5538.IBJU.2013.0086

Scopus: View on Scopus

PubMed: 26401874

Document Type: Article

Access: All Open Access; Gold Open Access; Green Open Access


Authors and Affiliations

Wishahi M., Department of Urology, Theodor Bilharz research Institute, Cairo, Egypt; Elganzoury H., Department of Urology, Theodor Bilharz research Institute, Cairo, Egypt; Elkhouly A., Department of Urology, Theodor Bilharz research Institute, Cairo, Egypt


Abstract

Background: Uretero-ileal anastomotic stricture (UIAS) is a urological complication after ileal neobladder, the initial management being endourological intervention. If this fails or stricture recurs, surgical intervention will be indicated. Design and Participants: From 1994 to 2013, 129 patients were treated for UIAS after unsuccessful endourological intervention. Unilateral UIAS was present in 101 patients, and bilateral in 28 patients; total procedures were 157. The previous ileal neobladder techniques were Hautmann neobladder, detubularized U shape, or spherical shape neobladder. Surgical procedures: Dipping technique was performed in 74 UIAS. Detour technique was done in 60 renal units. Ileal Bladder flap was indicated in 23 renal units. Each procedure ended with insertion of double J, abdominal drain, and indwelling catheter. Results: Follow-up was done for 12 to 36 months. Patency of the anastomosis was found in 91.7 % of cases. Thirteen patients (8.3%) underwent antegrade dilatation and insertion of double J. Conclusion: After endourological treatment for uretero-ileal anastomotic failure, basically three techniques may be indicated: dipping technique, detour technique, and ileal bladder flap. The indications are dependent on the length of the stenotic/dilated ureteral segment. Better results for long length of stenotic ureter are obtained with detour technique; for short length stenotic ureter dipping technique; when the stenotic segment is 5 cm or more with a short ureter, the ileal tube flap is indicated. The use of double J stent is mandatory in the majority of cases. Early intervention is the rule for protecting renal units from progressive loss of function.


Keywords

Surgical Flaps; Urethral Stricture; Urinary Bladder; Anastomosis, Surgical; Constriction, Pathologic; Cystectomy; Dilatation; Female; Follow-Up Studies; Humans; Ileal Diseases; Male; Postoperative Care; Ureteral Obstruction; Ureterostomy; Urologic Surgical Procedures; adverse effects; anastomosis; bladder; follow up; human; procedures; urologic surgery


Citation Information

Scopus Citations: 7


For comprehensive information about the Theodor Bilharz Research Institute (TBRI), its institutional activities, scientific and research achievements, clinical and hospital services, and the diverse expertise offered through its 22 specialized research and clinical departments, as well as opportunities for professional training, specialized workshops, and scientific conferences, readers are invited to visit the Institute’s official website.

The website provides regularly updated information on the Institute’s latest news, research activities, scientific initiatives, clinical services, institutional programs, and academic and professional opportunities.

English Website: https://www.tbri.sci.eg/en/

Arabic Website: https://www.tbri.sci.eg/ar/

Prepared and Uploaded by:

Abdalla F. Abdalla

Electronic Portal Unit

Electronic Portal Unit

Popular Posts

A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium–salicylate luminescent platforms for GPC3-targeted early HCC diagnosis

Mytilus edulis-mediated green synthesis of selenium nanoparticles with antimicrobial and molluscicidal applications

Holothuria arenicola Extract-Loaded Polycaprolactone Nanocapsules Attenuate Bile Duct Ligation-Induced Acute Liver Injury

Corrigendum to ‘Eco-friendly approach for the removal and simultaneous detection of cyanide toxins from drinking and wastewater sources’ [Environ. Pollut. 385 (2025) 127094]

Microbial levan potentiates hepatic retention and antitumor activity of a PEGylated benzimidazole–curcumin nanocomplex through TLR2–FXR/FGF15-associated immunometabolic remodeling in experimental liver cancer

Climate change and schistosomiasis: the impact of rising temperatures on snails transmitting schistosoma species

Upcycling low-density polyethylene waste into 1D fishbone nanofibers and 2D graphene nanoribbons for enhanced antibacterial applications