Impact of different preparation methods on the in vitro quality of 8 days storage platelet concentrates

Theodor Bilharz Research Institute

Bibliographic Information

Authors: El-Sayed H.; Hassanein A.; Fawzy R.; Zahran M.; Mahmoud O.; Yacoub E.; Moustafa A.

Journal: Life Science Journal

Publication Date: 2014

Volume / Issue: Volume 11 / Issue 1

Pages: 50–57

Article No.: 7

ISSN: 10978135

Scopus: View on Scopus

Document Type: Article


Authors and Affiliations

El-Sayed H., Haematology Department, Theodor Bilharz Research Institute, Egypt; Hassanein A., Haematology Department, Theodor Bilharz Research Institute, Egypt; Fawzy R., Clinical Pathology Department, Cairo University, Egypt; Zahran M., Haematology Department, Theodor Bilharz Research Institute, Egypt; Mahmoud O., Haematology Department, Theodor Bilharz Research Institute, Egypt; Yacoub E., Haematology Department, Theodor Bilharz Research Institute, Egypt; Moustafa A., Clinical Pathology Department, Cairo University, Egypt


Abstract

Background: Adequate prolongation of platelet (PLT) shelf life can achieve improved availability, logistical management and decreased wastage. The coupling of reliable methods of bacterial detection and optimum methods of platelet preparation can preserve the quality of platelets with extended storage. Objectives: This study aimed at evaluating the applicability of extending platelet shelf life up to 8 days, using different methods of platelet preparations. Subjects and methods: Thirty six platelet concentrates (PCs) were collected and divided into 3 equal groups, according to preparation procedure: Group (1): Non-leucofiltered random-donor PLTs (RDPs); Group (2): Leucofiltered RDPs; and Group (3): Single-donor aphaeresis PCs. All units were stored at 22-24oC on a flatbed agitator for 8 days. PLT characteristics and metabolic variables, CD62p and CD63 expression and RANTES levels, were assessed on days 1, 5 and 8 of storage. Besides, automated bacterial screening was performed on days 1 and 8 using BACTEC blood culture system with aerobic medium. Results: Until the end of shelf life, the mean PLT recovery, mean PLT volume (MPV), PLT distribution width (PDW), swirling scores, glucose and lactate dehydrogenase (LDH) levels showed best suitable values among the aphaeresis units, compared to the other 2 groups. pH was maintained > 6.8 in all groups. Also, the lowest expression of CD62p and CD63 was found among group 3, on day 8, compared to the other groups. However, RANTES results showed highly significant lower levels in groups 2 and 3 compared to group 1 on all days. No bacteriological growth was detected in all PC units, till day 8 of storage. Conclusion: Aphaeresis units could provide the highest quality with 8 days storage, particularly when assisted by a good and rapid bacterial detection system. Thus, the choice between different methods of preparing PCs with extended shelf life should depend on a critical balance between safety, quality and cost.


Keywords

Aphaeresis PCs; BACTEC; Leucofiltered random PCs; Non-filtered random PCs; Platelet storage


Citation Information

Scopus Citations: 2


For comprehensive information about the Theodor Bilharz Research Institute (TBRI), its institutional activities, scientific and research achievements, clinical and hospital services, and the diverse expertise offered through its 22 specialized research and clinical departments, as well as opportunities for professional training, specialized workshops, and scientific conferences, readers are invited to visit the Institute’s official website.

The website provides regularly updated information on the Institute’s latest news, research activities, scientific initiatives, clinical services, institutional programs, and academic and professional opportunities.

English Website: https://www.tbri.sci.eg/en/

Arabic Website: https://www.tbri.sci.eg/ar/

Prepared and Uploaded by:

Abdalla F. Abdalla

Electronic Portal Unit

Electronic Portal Unit

Popular Posts

A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium–salicylate luminescent platforms for GPC3-targeted early HCC diagnosis

Mytilus edulis-mediated green synthesis of selenium nanoparticles with antimicrobial and molluscicidal applications

Holothuria arenicola Extract-Loaded Polycaprolactone Nanocapsules Attenuate Bile Duct Ligation-Induced Acute Liver Injury

Corrigendum to ‘Eco-friendly approach for the removal and simultaneous detection of cyanide toxins from drinking and wastewater sources’ [Environ. Pollut. 385 (2025) 127094]

Microbial levan potentiates hepatic retention and antitumor activity of a PEGylated benzimidazole–curcumin nanocomplex through TLR2–FXR/FGF15-associated immunometabolic remodeling in experimental liver cancer

Climate change and schistosomiasis: the impact of rising temperatures on snails transmitting schistosoma species

Upcycling low-density polyethylene waste into 1D fishbone nanofibers and 2D graphene nanoribbons for enhanced antibacterial applications